Finned copper tube gas boilers & water heaters – Boiler Manual20WARNING: If you do not follow these instructions exactly, a fire or explosion may result causingproperty damage, personal injury or loss of life.FOR YOUR SAFETY READ BEFORE OPERATINGA. If this appliance is equipped with an electronicignition device, this automatically lights the burner. Donot try to light the burner by hand.B. BEFORE OPERATING smell all around the appliancearea for gas. Be sure to smell next to the floor becausesome gas is heavier than air and will settle on the floor.C. Use only your hand to push in or turn the gascontrol knob. Never use tools. If the knob will not pushin or turn by hand, don't try to repair it, call a qualifiedservice technician. Force or attempted repair may re-sult in a fire or explosion.D. Do not use this appliance if any part has been underwater. Immediately call a qualified service technician toinspect the appliance and to replace any part of thecontrol system and any gas control that has been underwater.OPERATING INSTRUCTIONS1. Set the thermostat to lowest setting.2. Turn off all electric power to the appliance if service isto be performed.3. Remove control access panel.1. STOP! Read the safety information above.2. Set the thermostat to lowest setting.3. Turn off all electric power to the appliance.4. This appliance is equipped with an ignition device, whichautomatically lights the pilot. Do not try to light the pilotby hand!5. Remove control access panel.6. Push in gas control knob slightly and turn clockwiseto “OFF”.7. Wait five (5) minutes to clear out any gas. Then smell forgas, including near the floor. If you smell gas, STOP!Follow “B” in the safety information above (to the left)on this label. If you do not smell gas, go to the next step.8. Turn the gas control knob counterclockwise to“ON”.9. Replace control access panel.10. Turn on all electric power to the appliance.11. Set thermostat to desired setting.12. If the appliance will not operate, follow the instructions“TO TURN OFF GAS TO APPLIANCE” and call yourservice technician or gas supplier.TO TURN OFF GAS TO APPLIANCE4. P u s h i n g a s c o n t r o l k n o b s l i g h t l y a n d t u r nclockwise to “OFF”. Do not force.5. Replace control access panel.OFFONGAS CONTROL KNOBPRESSURE REGULATORADJUSTMENT (UNDERCAP SCREW)OUTLET PRESS. TAPGAS INLET GAS OUTLETGROUNDTERMINALS (2)INTERMITTENT PILOT - HONEYWELL VR8304ADANGER: Propane gas may not always be detectedby smell. Propane gas is heavier than air and cancollect in low areas.Propane gas can ignite or explode if an ignitionsource is present and result in death, serious injuryand property damage!FOR YOUR SAFETY:• Have only qualified licensed professionals install,service and maintain this appliance and your gassystem in accordance with all applicable codes.• Install a nationally listed combustible gas detector(s)in your home.• If you suspect a leak:1. Have everyone leave the building immediately.2. Do not attempt to light any appliance.3. Do not touch any electrical or electronic switchesin the building.4. Do not use any phone in the building.5. Call your gas supplier from a phone outside ofthe building.6. If you cannot reach your gas supplier call the firedepartment.