S-AGR08-Egb07 05/15 - 3 Page 3 of 37 Commissioning and Operation7.5 Adjusting the jet geometryNote!The gun has a variable jet geometry to produce a round or flat spray pattern.You should only work with clean, dry, filtered, oil-free air.1. Select a suitable air flap.2. Position the air distributing ring to producethe desired jet geometry.3. Make the appropriate setting for the atomiser air.4. Make the appropriate setting for the horn air.7.5.1 Distance to workpiecePositon the automatic gun AGR-08-E about 15 to 30 cm from the workpiece.Positionfor verticalspray patternPositionfor horizontalspray pattern