ESP-SMT Smart Modular Control System25S The CYCLE/SOAK screen will appearwith 0° - 2° blinking.a. Use the up or down arrowbutton(s) to select the slope degreecategory representative of thezone topography. Press the NEXTbutton.b. The Automatic Cycle and SoakMode will blink. If you agree with theautomatically calculated maximumcycle value and the minimum soakvalue, press the NEXT button.c. If you want to change theautomatically calculated cycle andsoak values, press either the - or +button(s) and Custom will blink.Press the NEXT button.d. The Maximum Cycle value will blink.Use - or + button(s) the to increaseor decrease the maximum cycletime. Press the NEXT button.e. The Minimum Soak value will blink.Use the - or + button(s) to changeto the desired minimum soak timevalue.f. Press the NEXT button. The PlantType screen will appear.SCYCLE/SOAKSelect Slope in Deg.0-2° 3-4°5-7° 8°-upCycle/Soak AutomaticMax Cycle MinMin Soak (6)(40) MinZone xxNEXTBACKSCYCLE/SOAKSlope in Deg. 8°-upCustomCycle/Soak ModeMax Cycle MinMin Soak (4)(32) (4)(32) MinZone xxNEXTBACKSCYCLE/SOAKSlope in deg.Cycle/Soak Mode8°-upAutomatic CustomMax Cycle MinMin Soak (4)(32) (4)(32) MinZone xxNEXTBACKSCYCLE/SOAKSelect Slope in Deg.0-2° 3-4°5-7° 8°-upCycle/Soak AutomaticMax Cycle MinMin Soak (6)(40) MinZone xxNEXTBACKSCYCLE/SOAKSlope in deg.Cycle/Soak Mode8°-upAutomatic CustomMax Cycle MinMin Soak (4)(32) (8)(32) MinZone xxNEXTBACKSCYCLE/SOAKSlope in Deg. 8°-upCustomCycle/Soak ModeMax Cycle MinMin Soak (4)(32) (8)(50) MinZone xxNEXTBACKb.a. e.f.d.c.