INSTALLATIONCheck the appliance is electrically safe when you have finished.21ArtNo.090-0028 - 90 cooker min spacing GENERICAll dimensions are in mm650 min.5 5420 min.Fig.7-120 mmFig.7-2Positioning the CookerFig.7-1 shows the minimum recommended distance from thecooker to nearby surfaces.The cooker should not be placed near the fridge or on a base.The hotplate surround should be level with, or above, anyadjacent work surface.The cooker is designed to fit between kitchen cabinetsspaced over 600 mm apart. 5 mm clearance either side of theappliance is recommended to allow removal of the cooker forservicing.For non-combustible surfaces (such as unpainted metal orceramic tiles), this can be reduced to 25 mm.A minimum space of 650 mm is required between the top ofthe hob and a horizontal combustible surface.*Any cookerhood should be installed in accordance with thehood manufacturer’s instructions.**Any splashback must be fitted in accordance with themanufacturers instructions.It is recommended that there is at least 20 mm space betweenthe back cover of the cooker and the wall, for air circulation(Fig.7-2).Adjacent kitchen furniture must be heat resistant to 90 °C.Levelling the CookerThe cooker stands on four levelling legs. These can beadjusted 0 mm to 30 mm by turning the legs clockwise.It is recommended that you use a spirit level on a shelf in oneof the ovens to check for level.Moving the Cookernn On no account try and move the cooker while it isplugged into the electricity supply.nn The cooker is very heavy, so take great care.nn Do not try to lift or move the cooker by pulling onthe door handles.We recommend that two people manoeuvre the cooker.Make sure that the floor covering is firmly fixed, or removed,to prevent it being disturbed when moving the cookeraround.