3Manual No. 016-0230-090 21PowerGlide PlusInstall the PowerGlide Plus WiringWiring ConnectionsFor wiring connections made outside the cab, apply dielectric silicone grease (P/N 222-0000-006) generouslyon both the male and female ends of the connectors. Application of the grease will prevent corrosion to thepins and wires.Install the AutoBoom NodeFIGURE 14. AutoBoom Node Installed1. Mount the AutoBoom node (P/N 063-0130-010) to the valve mounting plate (P/N 107-0171-802) using three3/8”-16 zinc hex bolts (P/N 311-0054-106) and three 3/8”-16 zinc flanged lock nuts (P/N 312-1001-164).2. Insert the large, rectangular node connectors on the AutoBoom harness cable (P/N 115-0230-045 or 115-0230-085) into the correct ports of the AutoBoom node.3. Tighten the bolts on the node connectors to secure the connections.Connect the Harness to the Boom Function Controls1. Locate the Left Press and Right Press connectors on the AutoBoom harness cable (P/N 115-0230-045 or115-0230-085).2. Route the connectors to the AutoBoom valve (P/N 063-0131-126).3. Connect the Left Press connector to Port G1 on the AutoBoom valve.4. Connect the Right Press connector to Port G4 on the AutoBoom valve.5. Locate the Left Solenoid and Right Solenoid connectors on the harness cable.CAUTIONAlways connect the power cable as the laststep in the wiring process and verify that thepower leads are connected with the correctpolarity. Reversing power leads can causesevere damage to the equipment.