Chapter 434 Spra-Coupe 7X60 (2010 & Newer) AutoBoom® Installation Manual6. Route and connect the machine’s right tilt cylinder raise hose to the installed fittings in Port RV of theAutoBoom valve.7. Install the 90° end of the supplied hydraulic hose (P/N 214-1000-540) on the installed fittings in Port RC ofthe AutoBoom valve.8. Connect the straight end of the installed hydraulic hose to the machine’s right tilt cylinder raise port in therod-end of the right tilt cylinder.9. Remove the accumulator manifold from the left tilt cylinder.10. Remove the machine’s cylinder-to-accumulator fitting from the rod-end of the left tilt cylinder.11. Install a 1-1/16” SAE O-ring (M) to 1-1/16” SAE O-ring (M) straight adapter fitting (P/N 333-0012-234) in theopen port.12. Install the 2-way normally open solenoid hydraulic valve (P/N 334-0002-082) in the accumulator manifold.13. Install the accumulator manifold on the installed adapter fitting.14. Remove the accumulator manifold from the right tilt cylinder.15. Remove the machine’s cylinder-to-accumulator fitting from the rod-end of the right tilt cylinder.16. Install a 1-1/16” SAE O-ring (M) to 1-1/16” SAE O-ring (M) straight adapter fitting (P/N 333-0012-234) in theopen port.17. Install the 2-way normally open solenoid hydraulic valve (P/N 334-0002-082) in the accumulator manifold.18. Install the accumulator manifold on the installed adapter fitting.Install the Load Sense HoseFIGURE 6. Fittings Installed on the Logic Valve1. Install the fittings in the appropriate ports of the logic valve (P/N 334-0003-075) as illustrated above.2. Tighten all fittings installed on the logic valve.3. Locate the machine’s auxiliary pump in the engine compartment.4. Disconnect the machine’s priority valve load sense hose form the auxiliary pump.5. Install Port 1 of the logic valve in the port from which the priority valve load sense hose was disconnected.6. Connect the machine’s priority valve load sense hose that was previously disconnected to Port 2 of the logicvalve.7. Install one end of the supplied hydraulic hose (P/N 214-1000-639) to Port 3 of the logic valve.8. Connect the other end of the supplied hydraulic hose to Port LSP on the AutoBoom valve.333-0012-176333-0012-297333-0012-297333-0012-298333-0012-176