Chapter 2: Advanced Operation 23How do I access User Calibration settings?You can only access the calibration mode from Standby mode:1. With the SmartPilot in Standby mode, press and hold the standby button for2 seconds. The display will change to show DISPLAY CAL.2. Press the disp button once, the display will now show USER CAL.3. Press auto to enter User Calibration.The first page of User Calibration will now be displayed.4. To access other User Calibration pages, press disp to scroll down through theitems within that grouping:5. When you reach an item you wish to adjust, use the -1, +1, -10 and +10 but-tons (as appropriate) to change the value.6. When you have made all the changes you want to make, press and holdstandby for two seconds to exit calibration mode and save changes.User Calibration pagesAutoTack angle (SAILBOAT only)The AutoTack angle is the angle through which the boat will turn when you selectan automatic tack.Gybe inhibit (SAILBOAT only)With gybe inhibit on:• you will be able to perform an AutoTack into the wind• to prevent accidental gybes, the SmartPilot will prevent the boat from per-forming an AutoTack away from the windWith gybe inhibit off, you can perform an AutoTack into or away from the wind.Screen Text OptionsAUTO TACK 40° to 125° in 1° stepsScreen Text OptionsGYBE STOP ON (Default) = Gybe inhibit on (gybes prevented)OFF = Gybe inhibit off (gybes permitted)