10g WARNINGTo reduce the risk of electric shock, fire, explosion, serious injury or death:ï Disconnect electric power to the washer before servicing.ï Never start the washer with any guards/panels removed.ï Whenever ground wires are removed during servicing, these ground wires must bereconnected to ensure that the washer is properly grounded. W00337989Figure 9Figure 86. TIMER ASSEMBLYa. TIMER REMOVAL (Metered Models):NOTE: DO NOT attempt to repair timer.1. Unlock and remove meter case servicedoor.2. Remove timer bracket cap screw,Figure 8.3. Slide timer bracket left to disengagebracket from shoulder screw. Lift timer andbracket up and out of meter case throughservice door opening as far as wires willpermit.NOTE: If only replacing clutch, proceed to step 7.4. Disengage wire harness terminal block plugfrom timer by pressing in movable lockingtabs (located on each side of terminal blockplug),Figure 9. Then pull terminal blockplug away from timer.5. Disconnect earth (ground) wire fromterminal on timer,Figure 9.IMPORTANT: To avoid an open circuit, DO NOTpull on terminal block wires when removing blockfrom timer as this could damage wires or terminalcrimpings. Before attaching wire harness terminalblocks to timer, make sure all male terminals ontimer are straight and are capable of acceptingterminals from wire harness terminal blocks.IMPORTANT: Be careful not to dislodge ordamage two timer motor lead wires while handlingtimer.NOTE: To avoid timer damage, do not allow timerto be struck on corners, edges of frame or ontimer shaft.6. Remove two screws holding timer to timerbracket,Figure 9.7. Loosen setscrew holding clutch to timershaft,Figure 10.TIMERBRACKETMETERCASEW334SE1AMETERCASECAPSCREWTIMERSHOULDERSCREWTIMERBRACKETATTACHINGSCREWSW237SE1ATERMINALBLOCK PLUGGROUND WIRETERMINALLOCKINGTABSGROUNDWIRETIMER