CONTROL UNIT SERIES AUS X8540643 - 26/08/2016 Rev.13 33TECHNICAL DATASafety category 2Power supply Vdc 24 20%Power requirement W 5 maxOutput Relay 2 N.O. contacts (2A; 250V)System Status Output 100mA; 24VdcMuting lamp output 24Vdc / 0,5 5 WResponse time ms 30 maxOperating modes Manual or Automatic, selectablefrom terminal blockExternal relay control 2 N.C. contacts (20mA; 24Vdc)Number ofconnectable photocells 1 ÷ 4Muting sensors input 2 sens. (24VDC; PNP; dark-on)Muting enable input 24VDC, PNPConnections Terminal block with protectionagainst reversal of polarityStatus indicators Led Power On – Photocell Status –Fail - Muting active - Override activeMax. length of connections m 100Operating temperature °C 0 ÷ 55Enclosure protection rating IP 20Terminal block protectionrating IP 2XFastening Fast attachment to rail accordingto EN 50022-35Dimensions (h x w x d) mm 99 x 35 x 114,5Weight g 215B10d 800.000Device lifetime 20 yearsSafety levelType 2 EN 61496-1:2013SILCL 1 IEC 62061(ed.1)Cat.2 EN ISO 13849-1:2008Load Number of Commutations PFHd * MTTFd # DCavg # PL # CCF #2A@230Vac1 every 30s 2,81E-08 25,94 98,89% c 80%1 every min 1,72E-08 49,82 98,78% c 80%1 every hour 6,63E-09 100,00 96,73% c 80%1 every day 6,47E-09 100,00 96,32% c 80%0,5A@24Vdc1 every 30s 5,03E-08 13,24 98,94% c 80%1 every min 2,81E-08 25,94 98,89% c 80%1 every hour 6,81E-09 100,00 97,05% c 80%1 every day 6,48E-09 100,00 96,36% c 80%* IEC 62061# ISO 13849-1