28 | Regency U31-10 Gas Fireplace Insert|28maintenanceTop View of pilot flameCorrect flame pattern has four strong blueflames: 1 flowing around the thermopile andthermocouple and 1 reaching towards therear burner and 1 toward the front(it doesnot have to be touching the burner).Top View of pilot flameIncorrect flame pattern will have small, prob-ably yellow flames, not coming into propercontact with the rear burner or thermopile.CAUTION: ANY SAFETY SCREENOR GUARD REMOVED FOR SER-VICING AN APPLIANCE MUST BEREPLACED PRIOR TO OPERAT-ING THE APPLIANCE.WARNING: DO NOT OPERATEAPPLIANCE WITH THE GLASSFRONT REMOVED, CRACKEDOR BROKEN. REPLACEMENT OFTHEGLASSSHOULDBEDONEBYA LICENSED OR QUALIFIEDSERVICE PERSON.MAINTENANCEINSTRUCTIONS1) Always turn the gas valve to off before cleaning.For relighting, refer to lighting instructions. Keepthe burner and control compartment clean bybrushing and vacuuming at least once a year.When cleaning the logs, use a clean soft paintbrush as the logs are fragile and easily dam-aged.2) Clean (never when unit is hot) appliance, doorand louvers with a damp cloth. Never use anabrasive cleaner.The gold louvers (and optionalgold door) may be scratched if abrasives areused to clean them.The heater is finished in a heat resistant paintand should only be refinished with heat resistantpaint (not with wall paint). FPI uses StoveBritePaint - Metallic Black #6309.3) Make a periodic check of burner for proper posi-tion and condition. Visually check the flame ofthe burner periodically, making sure the flamesare steady; not lifting or floating. If there is aproblem, call a qualified service person.4) The appliance and venting system must beinspected before use, and at least annually,by a qualified field service person, to ensurethat the flow of combustion and ventilation airis not obstructed.During the annual service call, the burnersshould be removed from the burner tray andcleaned. Replace the embers but do not blockthe pilot.5) Keep the area near the appliance clear andfree from combustible materials, gasoline andother flammable vapours and liquids.6) Each time the appliance is lit, it may causecondensation and fog the glass. This con-densation and fog is normal and will disap-pear in a few minutes as the glass heats up.Never operate the appliance without theglass properly secured in place, withbroken glass or with the door open.7) Verify proper operation after servicing.8) Periodically check the pilot flames, thereshould be three strong blue flames approx.3/4" long - 1 flame to the front burner, and1 to the thermopile and one to the left. Seediagrams below.If you have an incorrect flame pattern, contactyour FPI dealer for further instructions.CLOTHING OR OTHER FLAM-MABLE MATERIAL SHOULD NOTBE PLACED ON OR NEAR THEAPPLIANCE.If the glass gasket requires replacement use7/8" flat glass gasket (Part # 936-243) for the BayFront and for the Flush Front.DOOR GLASSREPLACEMENTYour Regency insert is supplied with high tem-perature, 5 mm Neoceram ceramic glass that willwithstand the highest heat that your unit will produce.In the event that you break your glass by impact,purchase your replacement from an authorized FPIdealer only, and follow our step-by-step instructionsfor replacement.Flush Glass ReplacementSlide old glass out of the side frames and replacewith new glass.WARNING: CHILDREN ANDADULTS SHOULD BE ALERTEDTO THE HAZARDS OF HIGHSURFACE TEMPERATURE ANDSHOULD STAY AWAY TO AVOIDBURNS OR CLOTHING IGNITION.YOUNG CHILDREN SHOULD BECAREFULLY SUPERVISED WHENTHEY ARE IN THE SAME ROOMAS THE APPLIANCE.LOG REPLACEMENTThe unit should never be used with broken logs.Turn off the gas valve and allow the unit to coolbefore opening door to carefully remove the logs.The pilot light generates enough heat to burnsomeone. If for any reason a log should needreplacement, you must use the proper replace-ment log. The position of these logs must be asshown in the diagram under Log Installation.NOTE: Improper positioning of logs maycreate carbon build-up and will alterthe unit’s performance which is notcovered under warranty.GLASS GASKET