38 | Regency Horizon HZ54E-10 Gas Fireplace|38 installation919-258a 05/14/13Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Brokenlogs can interfere with pilot operation.Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.*Satin black paint is included if touch ups are required.1 Rear Log2 Left Log3 Right Log4 Left Cross Log5 Right Cross Log6 Front Left Log Piece7 Front Right Log PieceLava embersPilot Hood - HZ54E onlyLog placement template - one each HZ54E /HZ40E135246 71. S hut off gas and electrical supply, allow unit to cool to room temperature.2. Remove fl ush glass door (see manual).3. Carefully remove the logs from the packaging and unwrap them.The logs are fragile, handle with care -never force into position.4. Ensure glass crystals are installed on the burner.HZ54E = 2lbs HZ40E=1.5lbs5. HZ54E only- Remove existing pilot hood - replace with pilot hoodprovided with log set.HZ54E - existing PilotHoodHZ54E - new PilotHoodHZ40E - log placement template -shown in place.6. Clip on log guides - position approximately 5" on either side of thepilot hood.7. Install Rear Log (1), by positioning cut out over pilot hood.8. Push the rear log gently back, until it hits the log guides.9. Place log placement template on the front fl oor of the unit.Ensure L and R sides are in the correct position. Secure template inplace with magnets (supplied) on each side.Log guidesLog 1 in position11HZ54E/HZ40EHZ54E/HZ40E - LOG INSTALLATIONoptional driftWood loG set installation