Regency Horizon HZ54E Gas Fireplace 9INSTALLATIONThis includes:1) Clocking the appliance to ensure the correctfiring rate (rate noted on label 41,500 Btu/h(NG), after burning appliance for 15 minutes.2) If required, adjusting the primary air to ensurethat the flame does not carbon. First allow theunit to burn for 15-20 min. to stabilize.CAUTION: Any alteration to the product thatcauses sooting or carboning that results in dam-age is not the responsibility of the manufacturer.LOCATING YOURGAS FIREPLACEA) Flat on WallB) Flat on Wall CornerC) Recessed into Wall/AlcoveD) CornerDiagram 11) When selecting a location for your fireplace,ensure that the clearances are met.2) The appliance must be installed on a flat, solid,continuous surface For example a wood, metalor concrete floor or in a raised (on the wall) ap-plication. The appliance must be installed ona metal or wood panel extending the full widthand depth of the appliance.3) The HZ54E Direct Vent Gas Fireplace can beinstalled in a recessed position or framed outinto the room as in A, B, C and D.See Diagram 1.INSTALLATIONCHECKLIST1) Locate appliancea) Room location (Refer to "Locating Your Gasfireplace" section)b) Clearances to Combustibles (Refer to"Clearances" section)c) Mantle Clearances (Refer to "MantelClearances" section)d) Framing & Finishing Requirements (Referto "Framing & Finishing" section)e) Venting Requirements (Refer to "Venting"section)2) Assemble Top and Side Standoffs (Refer to"Unit Assembly Prior to Installation).3) Slide unit into place.4) Install vent (Refer to "Venting Arrangement"sections).5) Make gas connections (Refer to "Gas LineInstallation section).6) Install 4 AA batteries into battery pack or optionalAC power adaptor.7) Test the pilot (Refer to "Pilot Adjustment"section).8) Test Gas Pressure (Refer to "Gas Pipe PressureTesting" section).9) Install standard and optional features. Refer tothe following sections:a) Optional Log Set Installationb) Glass Crystals/ Optional CeramicStonesc) Optional Firebox Base Pebblesd) Optional Reflective Panelse) Faceplate / Door Frame Overlayf) Remote Controlg) Wall Thermostath) Wall Switch10) Final check.Before leaving this unit with the customer, theinstaller must ensure that the appliance is firingcorrectly and operation fully explained tocustomer.4) This appliance is Listed for bedroominstallations using the standard Remote(millivolt thermostat system). Some areas mayhave further requirements, check local codesbefore installation.5) The HZ54E Direct Vent Gas Fireplaceis approved for alcove installations, see"Clearances" section for details.6) We recommend that you plan your installationon paper using exact measurements forclearances and floor protection before actuallyinstalling this appliance. Have an authorizedinspector, dealer, or installer review your plansbefore installation.Note: For vent terminations refer to "ExteriorVent Termination Locations" section.HEATWAVEDUCT SYSTEMOPTIONAL KIT #946-556The HeatWave Air Duct Kit increases theeffectiveness of your fireplace by dispersing warmair from the fireplace to remote locations in the sameroom or other rooms in your home.Up to two kits may be installed on the fireplace.Please Note: Only 1 HeatWave kit may be oper-ated at one time. This includes the internal bloweroption as well.OPTIONALHEAT RELEASE KIT#946-570The Heat Release Kit expels warm air from thefireplace to the outside of the building, allowingthe fireplace to be operated with less heat enteringthe room. The kit may be used on either the leftor right side.The HeatWave Duct Kit has differentclearance and framing requirements, checkthe HeatWave manual for details.