Regency Horizon® HZO60 Gas Fireplace | 1919|installationDRAIN INSTALLATION (RECOMMENDED)Although this fireplace is designed to operate outdoors safely, rain and other sources of moisture may enter the hearth area, which will cause water to col-lect inside the base of the unit.To prevent excessive water collection, the installer must provide a way to drain the water from the base of the unit by building or installing awater collector before positioning the fireplace in its location.INSTALLATION INSTRUCTIONSWhen planning for the installation of the unit, the framing height must be increased by 3/4", when installing a drain pan. Additional space below the unit willalso be required to plumb a drain line.1. Remove 4 screws to remove the rear access panel from the back of the unit - this will allow access to the drain hole at the base of the unit.2. On the exposed drain hole (see location below), install a PVC 3/4" threaded coupling reducer going from the top of the pan, down through the hole. Applya silicone-based sealant around the base and threads before installation.3. Holding the reducer coupling with a wrench, thread a 90° PVC elbow (from the underside of the unit) to the reducer until it is tight to the metal.Note: To assure proper drainage, that fireplace must be installed on a leveled surface4. Add additional piping to route the drain to an appropriate location.Drain hole location atbase of the unitThreadedReducer(PVC)ThreadedElbow@ 90°(PVC)Reducer and elbow can be purchased from your localhardware store.Cut notches into the topof the coupling reducer toprevent water pooling.Rear access panelDrain hole