16Regency IG35 Gas Inbuilt FireplacePREMIUM FLUSH FRONT INSTALLATION918-644b 06/23/081IG35PREMIUM FLUSH FRONT INSTALLATION6) Place the ECS manual control switch key pad on the outside of theopening in the faceplate and the control switch to the inside of thefaceplate.Align the holes and secure in place using the 2 bolts, washers,phenolic spacers, split lock washers and nuts. See diagram 3 forsequence. Diagram 4 shows ECS manual control switch mountedon faceplate.ECS Manual Switch7) Run the thermodisc wires thru the hole in the heat shield.Then place the grommet over the sleeve and tuck into the hole in theheat shield as shown in diagram 5.Grommet1) Unplug the power source.2) Remove the glass door.Left SideHeat ShieldDiagram 1Diagram 54) Unplug the CAT5 cable from the ECS manual switch included withthe unit. See diagram 2.5) Remove the 2 bolts, washers, phenolic spacers, split lock washersand nuts securing the manual control switch to separate the manualcontrol switch keypad. See diagram 2.Manual ControlSwitch KeypadBoltsDiagram 2Phenolic SpacerWasherSplit Lock WasherNutDiagram 3Diagram 4ECS Manual Control Switch Installation:3) Remove the heat shield from the left side of the faceplate by undoingthe 2 screws. See diagram 1.Control SwitchCAT5 CableReceptacleINSTALLATION