46 P33CE Direct Vent Gas FireplaceINSTALLATIONNOTE: Wiring schematics for P36E-4 (120 Volts),plug-in fan circuit with speed control switch on wall.LockwasherFanground wireNut#8 Ground Lug(for mobile home)Star washerGround GreenNeutralLiveBlack Red RedFan Thermodisc(normally open)GroundON OFFRotary SpeedControl120V AC60 HzFanOPTIONAL FAN WIRING DIAGRAMINSTALLING THE OPTIONAL FAN (INSTALLED UNIT)120 Volt AC power is needed for the fan switch and blower. The fan can be hardwired if desired. The grounded duplex receptacle should be installed into thesupplied receptacle box by a qualified electrician. The neutral (wider) slot of thepolarized receptacle should be at the top.Unit must be grounded at all times. Do not cut the ground terminal off underany circumstances.1. Shut the power off.2. Remove Flush door (See instructions in this Manual).3. Remove inner panels (See instructions in this Manual).4. Remove logs.5. Remove the burner by removing 2 screws in the locations shown below.Diagram 1: Remove the 2 screws to removeburner.Diagram 26. Slide burner to the left and lift out.(See Diagram 2).7. Remove 2 screws to remove Rear Log Stand (See Diagram 3).Diagram 3Rear Log Standscrews