Regency ® P36D-10 Zero Clearance Direct Vent Gas Fireplace | 35|35installationGAS LINEINSTALLATIONThe gas line is brought through the right of theappliance. The gas valve is situated on the righthand side of the unit and the gas inlet is on theright hand side of the valve.The gas line connection may be made of rigidpipe, copper pipe or an approved flex connector.(If you are using rigid pipe, ensure that the valvecan be removed for servicing.) Since somemunicipalities have additional local codes it isalways best to consult with your local authoritiesand the CAN/CGA B149 installation code.For USA installations follow local codes and/or the current National Fuel Gas Code, ANSIZ223.1.When using copper or flex connectors use onlyapproved fittings. Always provide a union sothat gas lines can be easily disconnected forservicing. Flare nuts for copper lines and flexconnectors are usually considered to meet thisrequirement.Important: Always check for gas leaks witha soap and water solution or gas leak detec-tor. Do not use open flame for leak testing.HIGH ELEVATIONThis unit is approved in Canada for altitude 0to 4500 ft. (CAN1 2.17-M91) with the orificesupplied.P36D-NG10 System DataFor 0 to 4500 feet altitudeBurner Inlet Orifice Sizes: #37Max. Input Rating: 30,000 Btu/hMin. Input Rating: 15,500 Btu/hSupply Pressure: min.5.0" w.c.Manifold Pressure(High): 3.8"+/- 0.2"w.c.Electrical: 120 V A.C. System.Circulation Fan: variable speed 130 CFM.Log Set: Ceramic fibre, 7 per set.Vent System: Simpson Dura-Vent DirectVent System or Regency Direct Vent System (Flex)P36D-LP10 System DataFor 0 to 4500 feet altitudeBurner Inlet Orifice Sizes: #52Max. Input Rating: 30,000 Btu/hMin. Input Rating: 15,000 Btu/hSupply Pressure min.12.0" w.c.Manifold Pressure(High) 11"+/- 0.2" w.c.Electrical: 120 V A.C. System.Circulation Fan: variable speed 130 CFM.Log Set: Ceramic fibre, 7 per set.Vent System: Simpson Dura-Vent Direct VentSystem or Regency Direct Vent System (Flex)