Regency ® P36D-10 Zero Clearance Direct Vent Gas Fireplace | 37|37installationCONVERSION FROM NG TO LPFOR P36D-10 USING SIT 829 NOVA GAS VALVE1 10.30.14919-472Conversion from NG to LPG forP36D-10 / P36-10THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTERIF IN DOUBT DO NOT DO THIS CONVERSION !!1. Shut off the gas and electrical supply.2. Remove the safety screen and face-plate.3. Open and remove the glass door.4. Remove the logs and embers (if alreadyinstalled).5. Remove the 2 screws holding the BurnerAssembly to the firebox base. Push theBurner Assembly to the left and lift out.6. Pull off the pilot cap to expose the pilotorifice.Remove the 2 screws, push Burner Assemblyto the left and lift out.7. Unscrew the pilot orifice with the allenkey; then replace with the LPG pilotorifice and the pilot cap, provided in thekit.8. Remove burner orifice with a 1/2"wrench. Use another wrench to hold onto the elbow behind the orifice. Discardorifice.9. Reinstall new burner orifice LPGstamped #52 and tighten.Burner OrificeConversion Kit Contains:Qty. Part # Description1 904-390 Burner Orifice #521 904-529 5/32" Allen Key1 918-590 Decal "Convertedto LPG"1 908-528 Red "LPG" label1 910-037 LPG Injector(Pilot Orifice)1 910-582 Stepper Motor1 919-472 Instruction SheetInstallation of LPGConversion Kit:10. Remove NG stepper motor by removing3 screws in locations shown below–re-place with LP stepper motor, secure inplace with 3 screws.Remove NG Stepper motor andreplace with LP Stepper motorInstaller Notice:These instructions must be leftwith the appliance.11. Check for gas leaks with a proper soapysolution or leak detector.12. Check for proper spark between theignitor and pilot cap. Refer to "LightingProcedure" section of the manual forlighting sequence.13. Check pilot flames. Correct flame patternhas 3 strong blue flames. Adjustmentcan be made by turning the slottedscrew at the top right corner of the valve.Refer to "Maintenance Instructions"section of the manual for correct flamepatterns.14. Check inlet (11" WC min) and outlet (10"WC) pressures. Refer to "Gas Pipe Pres-sure Testing" section of the manual.15. Reverse Steps 5 to 1.16. Attach the label "This unit has been con-verted to LP" near or on top of the serial# decal.17. Replace yellow "NG" label with red "LP"label.18. Check operation of flame control.1 9. Check for proper flame appearance andglow on logs.