Regency ® PG36-3 Gas Log Fireplace6INSTALLATIONMin. 6"(152mm)Min. 8"(203mm)30-1/2" (775mm)Top of UnitMin. 32" (1016mm)to Ceiling"Clearances for Bay or Flush FrontClearances for Barcelona FrontNOTE: The minimum floor clearance mustbe maintained from the top surface of thecarpeting, tile, etc.Minimum Clearance from Top of Unit to:Mantel* Minimum 7" (177mm)Ceiling from top of unit. 32" (1016mm)Side Wall ClearanceBay or Flush Front 6" (152mm)Barcelona Front 8" (203mm)Horizontal Flue ClearancesTop 2" (51mm)Side 1-1/2" (38mm)Bottom 1-1/2" (38mm)Vertical Flue Clearances 1-1/4" (32mm)Alcove Clearances**:Max. Depth 36" (914mm)Min. Width 48" 1219mm)Min. Height 72" 1829mm)* see mantle clearance instructions(Refer to the "Combustible Mantels," & "MantelLeg Clearances" sections.)**Approved for one sidewall installationonly when using Barcelona Front.CLEARANCESThe clearances listed below are Minimumdistances unless otherwise stated:A major cause of chimney related fires isfailure to maintain required clearances (airspace) to combustible materials. It is of thegreatest importance that this fireplace andflue system be installed only in accordancewith these instructions.Clearance to Combustibles from:Back 0" (0mm)Side 0" (0mm)Floor 0" (0mm)Diagram 1LOCATING YOURFIREPLACE1) When selecting a location for your fireplace,ensure that the clearances outlined on thispage are met.2) P r o v i d e a d e q u a t e c l e a r a n c e s f o rservicing.3) The appliance must be installed on a flat,solid, continuous surface (e.g. wood, metal,concrete). This may be the floor, or raised upon a platform to enhance its visual impact.If the appliance is going to be installedon carpeting, combustible linoleum tile orother combustible material other than woodflooring, the appliance must be installed ona metal or wood panel extending the fullwidth and depth of the appliance.4) The PG36 Co Axial Flue Gas Fireplacecan be installed in a recessed position orframed out into the room as in A, B, C, D.See Diagram 1.MANUFACTUREDMOBILE HOMEADDITIONALREQUIREMENTS1) Ensure that structural members are not cutor weakened during installation.2) Ensure proper grounding using the #8ground lug provided. Refer to the "Wiring"section.A) Flat on WallB) Flat on Wall CornerC) Recessed into Wall/AlcoveD) Corner5) This appliance is Listed for bedroominstallations when used with a Listed MillivoltThermostat. Some areas may have furtherrequirements, check local codes beforeinstallation.6) The PG36 Co Axial Flue Gas Fireplace isapproved for alcove installations, which meetthe clearances listed on this page.7) We recommend that you plan your installationon paper using exact measurements forclearances and floor protection beforeactually installing this appliance. Have anauthorized inspector, dealer, or installerreview your plans before installation.Note: For flue terminations see the"Exterior Flue Termination Locations"section.WARNINGFire hazard is an extremerisk if these clearancesare not adhered to.For more Barcelona Framing and InstallationNotes, see the "Framing and Finishing"section.BARCELONA FRAMING NOTE: If theBarcelona Trim is to be installed, the frontface of the fireplace must be made of non-combustible material. See Diagram 1.Diagram 1