Regency U31-3 Gas Fireplace Insert 9INSTALLATIONNOTE: Mantel clearances for Installation intoa Zero Clearance Kit are different. Pleaserefer to the Zero Clearance Kit Manual fordetails.MINIMUM FIREPLACEDIMENSIONSThe minimum fireplace dimensions for the FPIgas fireplace insert are shown in the followingdiagrams:Combustible Mantel Clearances inMasonry Installation8-1/8”Low profileNote: A non-combustible mantel may be in-stalled at alower heightif the framingis made ofmetal studsc o v e r e dwith a non-combustibleboard.INSTALLATIONCHECKLISTThe Regency Gas Insert is installed as listed below.1) Unit Location - check Clearances to Combus-tibles.2) Make the gas connections.Convert to Propane Gas if necessary.3) Install the flue or liner to the sliding draft hood.4) Install Venting. Slide the unit into the fireplace.Attach draft hood to the insert.5) Test gas pressure.. Check aeration6) Test for flue spillage.7) Install the optional brick panels.8) Install the log set.9) Assemble and install the faceplate and trim.10) Install the glass front.11) Install louvers.12) Install Optional Double Screen Door.13) Install Optional Remote Control and OptionalWall Thermostat.14) Final check: Before leaving this unit with thecustomer, the installer must ensure that theappliance is firing correctly. This includes:a) Clocking the appliance to ensure thecorrect firing rate.b) Adjusting the primary air, if required, toensure that the flame does not carbon.c) Ensuring that the appliance is ventingcorrectly.MATERIALS REQUIREDNo electrical power supply is required for the gascontrol to operate. A 120 Volt AC power cord ishooked up to the fan. Plug the 3 wire cord intoa suitable receptacle. Do not cut the groundterminal off under any circumstances. Whenconnected with 120 volts, the appliance must beelectrically grounded in accordance with local codes,or in the absence of local codes, with the currentCanadian Electrical Code CSA C22.1 (in Canada)or with the current National Electrical Code ANSI/NFPA 70-1987 (in U.S.A.).CLEARANCES TOCOMBUSTIBLESFrom UnitSides A 10" / 255 mmCeiling B 47.5" / 1205 mmMantle C See mantleclearancesMax. Mantel Depth G 12" / 305 mmMin. Alcove Width K 48" / 1220 mmMax. Alcove Depth L 36" / 915 mm* No Hearth RequiredNote: If you are installing the Excalibur Surround,the minimum fireplace dimensions are as follows:Width (at front): 29" (737mm)Depth: 16" (406mm)NOTE: This unit is equipped with a heat sensorthermodisc which will prevent the blowerfrom operating until the unit reaches thecorrect temperature.