1287654321RJ12SL6+ v.3.30 ENInstallationWiring diagramvoice stationscrew terminals*Input A is configured with either:• SafeLine Pro N/O (default) or N/C.• Parameter *89*, please refer to the correspondingcode in the ”Parameter List”.Connecting thetelephone lineConnect the telephone line parallell in universal terminals or theRJ-plug, see picture above. It’s possible to connect up to nineSL6+ main units to the same telephone line.In order to access the unit remotely, it needs to be assigned a unitnumber. Please refer to parameter *82* in the “Parameter List” formore information.Phone line is connected via RJ12 or terminal A through thefollowing:123456InputNot in useOutputOutputNot in useInput7. Bus GND8. Bus 12 VDC6. Not in use5. Input A*, alarm button4. Output B, green pictogram3. Output A, yellow pictogram1. Bus A2. Bus BA common mode choke must beused (2,2mH) for telephone line.