32E1 2 3 4 5 6SL6+ v.3.30 ENConfigurationAlarm status outputs• Relay will be activated when set time is reached.• Relay will be deactivated when emergencycall ends.Battery failure• Relay will be activated when the battery test has failed.• Relay will be deactivated by pressing the reset button.Pictogram yellow (only relay 1)• Relay will be activated when the alarm button is pressed (yellowpictogram).• Relay will be deactivated when the reset button is pressed or ifalarm centre presses “5”.Pictogram green (only relay 2)• Relay will be activated when the call is acknowledged (greenpictogram).• Relay will be deactivated when the call is disconnected.Activate with DTMF 8 (only relay 1)• Relay will be activated for 5 seconds when DTMF “8” is pressed.Activate with DTMF 9 (only relay 2)• Relay will be activated for 5 seconds when DTMF “9” is pressed.Manual reset• Relay will be activated when set time reached.Emergency call failure• Relay will be activated when the emergency call failed after 12attempts, ”Emergency Call Fail”.System failure• Relay will be activated when power (230 VAC) and PSTN/GSM netis OK.• Relay will be deactivated when power supply is gone more then15 min or when there is no GSM-net.Emergency bell• Relay will be activated when the emergency bell input is active.• Relay will be deactivated when the emergency bell input isdeactivated.Relay functionsThis applies for SW 4.00 or later.(For functions of earlier versions,please contact the Support team.)Relays 1 and 2 can beprogrammed independently.Call retry failure• Relay is activated when current relay is in Standby Mode.• Relay is deactivated if failing to deliver an alarm. If Fallback isactive, both interfaces have failed. Relay closes at successfuldeliverance.Automatic emergency button check• Relay is active once every day, checking emergency button.• Relay is deactivated when emergency button input is changed,or if DB collective fault is programmed on an output.