Connectors98-132904-C Chapter 2: Installation 2-13InstallationNMEA interface descriptionNMEA input: Impedance: 600 Ohm. Max. 2mA at min. level of 2VThe NMEA interface supports NMEA 0183 v2.0, v2.1 and v2.3. The following sentencesare supported:• GGA: UTC, "Position", "quality indicator" (indicators 1-5). All other fields are unused.• GLL: UTC, "Position", "Status" and "mode" (indicators A and D). All other fields areunused.• GNS: UTC, "Position" and "mode" (indicators A and D). All other fields are unused.• RMC: UTC, "Position", "Status", "Date" and "mode" (indicators A and D). All otherfields are unused.• ZDA: UTC, "Day", "Month", and "Year". All other fields are unused.In accordance with the standard EN61162-1:2008 and EN61162-2:1998.Figure 2-12: NMEA interface descriptionuP464k500R10k0OVccNMEA-HS in+NMEA-HS in-ABNMEA in-NMEA in+J3pin1 OO464k500R1k0AUXconnectorVccVccNMEA in+NMEA in-BAACCconnectorJ4pin2 Opin3 Opin4 Opin1 Opin2 Opin3 Opin4 O