UAIS DEBEG 3400, Electronics UnitED3047G142 / 08 (2004-06)Technical Manual6 Repair/Maintenance6.1 Trouble Shootingt_ue_e07.fm / 21.06.04526.1.2 Trouble Shooting for UAIS DEBEG 3400 connected to a RADARPILOT 10006.1.2.1 Indication: System Fault Message 3617 Displayed on IndicatorNOTE:The following instructions are valid only, if the AIS is connected via the Primary Display Port. TheUAIS DEBEG 3400 Electronics Unit can also be connected via the Ethernet LAN (RADARPILOT/CHAR-TRADAR 1000 with software 3.0 or newer or MULTIPILOT 1000).Procedure:1. Check the cabling of the Sensor Input Channels and the Primary Display port. See the TechnicalManual of the UAIS DEBEG 3400 and or the Technote T0211-340x-002 for further information.2. Check the correct setting of the S1 and the jumpers of the Interface Assembly SH3014G203. S1must be set to position 2. No jumpers should be connected to the pins 1...4. See the TechnicalManual of the RADARPILOT 1000 for further information.If the system fault message is still existing, the communication on the Primary Display Port must bechecked. Proceed as follows:Test of the RADARPILOT/CHARTRADAR/MULTIPILOT 1000 Output1. Power Down the system2. Connect the AIS output TB14 and TB15 of the Analog Interface additionally to an indicator serialinterface (TB1) of the radar. If there is a free input, this one should be used. If all inputs are used,one of them must be disconnected. Figure 6-1 shows the connection to the serial interface No. 4 asan example.Fig. 6-1 Cable connection for the interface monitoring Radar > AIS3. Power on the radar. Configure the concerned indicator serial interface by means of the System Main-tenance Manager as followsAnalog InterfaceInterconnection BoardRADARPILOT/CHARTRADARMULTIPILOT 1000UAIS Electronics UnitPrimary Display Port81016Output -AIS RxD, Input -RxD4, Input +Output +AIS RxD, Input +RxD4, Input -Input -AIS TxD, Output -Input +GNDAIS TxD, Output +GNDConnector 2TBTB1 Indicator Serial Interface 461451151671117z_ue_025.eps