39RIS 700_1200_1900_2200 HE/HW EKO 3.0[ dk ] [ ru ] [ en ] [ de ]1_790.0047A.0.1.1-L-0k111012L X31X33.15X33.16 COMA.0.1024VDC24VDCX41.1X41.2X39.2X39.1X38.1X38.2X40.3X40.2X40.1X34.8X34.7X34.6X34.5X34.4X34.3X34.2X34.1X33.26X33.25X33.17X33.12X33.18X33.14X33.13X35.1X35.2Y1 - Control OPEN (AC 24 V)Y2 - Control CLOSE (AC 24 V)G - System potential AC 24 V24VDCX16.1 21 3X33.5X33.4X33.3 VAL+VAL-VALY1 Y224VAC, 3-positionM5 G1114COMB.0.104 5 6 7X21.212PS1 PS2DX CoolingP13LN X25X2923PTransmitter 1 (24 VDC)23 - 24V DC,24 - intput, 0-10V DC,25 - GND,24 25FANCOM1211Fan run1.2W max+24X16.4 9 106541.2W maxFan fallANTI.FCOMX33.11ALARMX16.3 7 8R1 A1A2X33.10COMX33.9CHILX33.2MIDLX33.1COMX32.3TIMEX32.2HIGHX32.4COMX32.1LOWTLX37LON/OFF ON/OFF230V AC230V AC20LLNN L1817 19M3M2X16.5X16.6 21 221413TARG1Remote controlRS485_1TJCOMT.OUTRS485_1NLX8COML (close)NX33.13X10EXT-EXT+AC.NL (open)L controlEXT+EXT-EXT-EXT+NNNL controlL supplyNX35.5X35.4X35.3X33.21X33.22TJT.WATCOMX33.20X33.19X52 TETEA3A3A2A2A1A1RS485_2RS485_2ModBus RTUX3X4X37.4X37.3 V2COMX37.1X37.2X42X12COMV1NLAC.NPUMPA4A4HR21PS3X16.215 16E10-10VinPENLK1(11)K1(14)IVGNDE10-10VinX34L2L1NPEL1L2L3NPE 123456789987654321X4X3PENLK1(11)K1(14)PVGNDX3210AF11 2T.setCOMX33.23X33.2426 27 28PTransmitter 2 (24 VDC)26 - 24V DC,27 - intput, 0-10V DC,28 - GND,L1PE NQ11 342PE NX23BOOSTSTOP-NOSTART-NCJumperL1NX16.7PEN X24X35L2L1NPEL1L2L3NPE X3321N LPEKE2 AT2CX16.10DMPX33.8DMP-X33.7DMP+X33.624VDC, 0-10VDCM6GY00 - GND,Y - 0-10V,G - 24VDC.32X16.8 33 3429X16.7 30 311A21F2N LM4PE1f, 230V ACmax. 1AX16.9 35 36 T1TV1 4Spring back321 X21.18 9X21.31x230V, 50Hz24VAC3-positionM11 - GND2 - AC24V open3 - AC24V close21X403CEE7/7PV - supply air fan.IV - extract air fan.KE2 - control box heater.AT2 - automatic reset thermostat for control boxheater.TL - outside air temperature sensor.TJ - supply air temperature sensor.TE - exhaust air temperature sensor.DTJ100 - extract air humidity + temperaturesensor.T1 - antifrost thermostat.TV - antifrost sensor.M1 - BYPASS damper actuator 24VDC,M2 - outside air damper actuator.M3 - extract air damper actuator.M4 - water heater circulatory pump.M5 - water cooler valve actuator.M6 - water heater valve actuator.FA - fire alarm input.PS1 - supply air differential pressure switch.PS2 - extract air differential pressure switch.PS3 - antifrost pressure relay.P/U - "Transsmiter 1" supply air pressuretransmitter (0-10 VDC).P/U - "Transsmiter 2" extract air fan 0-10Vpressure, CO2 transmitters.Q1 - main switch.F1 - fuse BT-5x20-10.F2 - fuse BT-5x20-1.R1 - relay.FANCJumper+5VTACOMRHHRU TADTJ 100.1RDWH321BK RD WH