Instruction ManualModel No CT100Cylinder / Pipe ThermostatMAINTENANCEThe CT100 thermostat requires no specialmaintenance. Periodically, the outer casing can bewiped clean using a dry cloth (please DO NOT usesolvents, polishes, detergents or abrasive cleaners,as these can damage the thermostat).There are no user serviceable parts within the unit;any servicing or repairs should only be carried outby Salus Controls or their appointed agents.Should the CT100 thermostat fail to functioncorrectly, check:• The CT100 temperature has been set correctly.• Heating system time switch or programmeris switched on.CT100 INSTRUCTION MANUAL7WARRANTYSalus Controls warrants that this product will befree from any defect in materials or workmanship,and shall perform in accordance with itsspecification, for a period of two years from thedate of installation. Salus Controls sole liability forbreach of this warranty will be (at its option) torepair or replace the defective product.CT100 INSTRUCTION MANUAL8PRODUCT SPECIFICATIONModel: CT100Type: Surface mounted mechanicalthermostat designed for hot watercylinder or pipe applications.DimensionsHeight: 105 mmWidth: 45 mmDepth: 50 mmSwitchingSwitching Voltage: 230V AC, 50HzSwitching Current: 16A resistive, 4A inductiveContact Type: Single Pole Double Throw (SPDT)TemperatureRange: 40 ºC to 80 ºCEnvironmentOperating Temperature: 0 ºC to + 55 ºCStorage Temperature: - 20 ºC to + 60 ºCCT100 INSTRUCTION MANUAL9Sales:Email: sales@salus-tech.com Tel: 01226 323961TechnicalEmail: tech@salus-tech.com Tel: 01226 323961Salus Controls plc, Salus House, Dodworth Business Park South,Whinby Road, Dodworth, Barnsley S75 3SPsalus-tech.CT100 Manual_Layout 1 24/04/2013 10:31 Page 1