Dip switches7.1, SPANSpan is the temperature difference between the turn on temperature and turn offtemperature. 1°C or 2°C of span can be selected and the effect is summarizedin the following table:Span Heating System Cooling System1°CO nwhen.....Tr<=Ts-0.5 Tr>=Ts+0.5O f fwhen.....Tr>=Ts+0.5 Tr<=Ts-0.52°CO nwhen.....Tr<=Ts-1.0 Tr>=Ts+1.0O f fwhen.....Tr>=Ts+1.0 Tr<=Ts-1.0Ts: Set temperatureTr: Room temperatureFor example, if you set the temperature to 20°C and span = 1, the heater willoperate when the room temperature drops to 19.5°C and turns off when thetemperature rises to 20.5°C7.2, Output-on 5 minutes delayWith this switch enabled, the external system will switch on only if it has beenoff for more than 5 minutes. If cooling system is selected, this function will beactivated automatically.7.3, Heat/Cool system selectTo select whether a heating or a cooling system to be controlled. Note that nor-mally for a heating system the comfort temperature is higher than the economytemperature, while it is reverse for a cooling system.Span = 2CoolSpan = 1HeatDelay EnableDelay Disable8, Controlling a cooling systemBy setting the dip switch, the thermostat can be used to control a cooling system.The operation is similar to that of heating system. However, there are somedifferences between them, as the following list:1, In general the comfort temperature of a cooling system is lower than theeconomy temperature.2, The switching is reversed: The thermostat switches on the system when theroom temperature is higher than the set temperature.3, There is no more defrost temperature. The snow () and 7°C will not be displa-yed. If you select program 0 the thermostat will switch off the cooling system.4, The 5 minute minimum cycle time is enabled automatically, regardless of thesetting of the dip switch.Inside the packaging you should find1 Euro-thermostat 2 #6 x 1” screws2 wall anchors 1 drilling template1 user manualSalus Controls plcSalus House,Dodworth Business Park South,Dodworth, Barnsley, S75 3SPWeb: www.salus-tech.com