Doc.-ID: 160720-PT08BA-SS-ExCam IPP5635_en_rev.00.docx, page 15 of 24Table 5.2 – Pin assignment SKDxx and plug contact RJ45Figure 5.6 – RJ45 Contact assignmentParticularly in EMC critical environments, it is important to earth the shield at the terminalblock side (q.v. figure 5.3 – pin with black shrink tubing and blue ferule).Figure 5.7 – SKDxx Pin assignmentIn case the ExCam IPP5635 is supplied via a PoE capable device, an additional safe-guarding of the power supply is not necessary. The power supply is executed by the PoEnetwork device via an electronic with intelligent set-up. The camera as well as the con-nection is permanently monitored in order to avoid any failure or defects in case of ashort-circuit fault.For a camera with terminal block execution, it is possible to operate the camera eitherwith a PoE capable network device or with a separate 48 V DC power supply (supplyvoltage and network streams are self-sustaining). In this event an adequate supply safe-guarding has to be dimensioned.Recommended is a 300 mA medium time lag fuse.4 2639 (shield/GND)587110 (shield)9