6Installation ProcedureEnglishInstallation Procedure• Construct a protection wall with a solid material suchas concrete to block the sea breeze. Make sure that theheight and the width of the wall are 1.5 times largerthan the size of the outdoor unit. Also, secure a spacelarger than 700 mm between the protection wall andthe outdoor unit for exhausted air to ventilate.Protection wallOutdoor UnitSea breezeSeaCAUTION• Depending on the condition of power supply, unstablepower or voltage may cause malfunction of the partsor control system. (At the ship or places using powersupply from electric generator...etc)• Install the unit in a place where water can drain smoothly.• If you have any difficulty finding installation location asprescribed above, contact your manufacturer for details.• Be sure to clean the sea water and the dust on theheat exchanger of the outdoor unit and apply acorrosion inhibitor on it. (At least once in a year.)Outdoor unit dimensionsA TypeAC140KXAPEH/SA, AC125KXAPEH/SP620330384360142013959405675581095Electricalcomponent boxB TypeAC100KXAPEH/SA, AC125KXAPEH/SAAC100KXADGH/SA, AC140KXADGH/SA62033038436012101185940567558675Electricalcomponent boxC TypeAC071KXAPEH/SA, AC071KXADEH/SA880 5331066036418798Minimum clearances for the outdoor unitWhen installing 1 outdoor unit(Unit: mm)300 or more1500 or more300 ormore600 ormore 300 ormore2000or more1500or more600or more300or more1500or more300 ormoreWhen installing more than 1 outdoor unit(Unit: mm)1500or more600or more3000or more3000or more300or more600or more600or more1500or more 300or more360_AC_Outdoor_AU_Eng_EN.indb 6 2016-09-20 오후 8:00:28