E-16COMPLETING THE I NSTALLATIONPurging the Connected Pipes(Continued)Important information regulation regarding therefrigerant usedRefrigerant type GWP valueR410A 1975 GWP=Global Warming PotentialThis product contains fluorinated greenhouse gases covered by the KyotoProtocol. Do not vent gases into the atmosphere.Please fill in with indelible ink,- the factory refrigerant charge of the product,- the additional refrigerant amount charged in the field and- + the total refrigerant charge.on the refrigerant charge label supplied with the product. The filled-out label must be adhered in the proximity of the productcharging port (e.g. onto the inside of the stop valve cover).Indoor unitOutdoor unit= ( ) kg= ( ) kg += ( ) kgContains fluorinated greenhouse gasescovered by the Kyoto Protocol.Note a. Factory refrigerant charge of the product: see unit name plateb. Additional refrigerant amount charged in the field(Refer to the above information for the quantity of refrigerantreplenishment.)c. Total refrigerant charged. Refrigerant cylinder and manifold for chargingab cdAdding RefrigerantAdd refrigerant charge according to table below: If you use a pipe... Then...longer than 5 meters, 'A'g of refrigerant R410A mustbe added for each extra metre.shorter than 5 meters, The purge time is normal.Model AAQ09/12VBC 0AQ09/12NSBAQ09/12FC15AQ09/12NSA18/24Charging the refrigerant under conditions of liquid byusing a liquid pipeR410A is a mixed type of refrigerant. It is necessary for recharging underconditions of liquid. When recharging refrigerant from the refrigerant cylinderto the equipment, follow the instructions below.Before recharging, check whether the cylinder has a siphon or not.There are two ways to recharge the refrigerant.Note If R410A refrigerant is charged with gas, the composition of thecharged refrigerant changes and the characteristics of theequipment vary. During the measuring operation of refrigerant quantity added usean electronic balance. If cylinder doesn’t have syphon, upset it. Charge the refrigerant standingthe cylinder upright.Cylinder with siphon Charge the refrigerant turning thecylinder upside down.Cylinder without siphonsiphon08'FORTE_VIVACE_Inv_IM_28492A£¨4£©_E.indd 16 2007-12-6 9:32:58