E-4installing the air condtionerWhen you install the unit, make first refrigerant connections and then electricalconnections. Connect the air conditioner to grounding system beforeperforming the electrical connection. If unit is uninstalled first disconnectelectrical cables, then refrigerant connections.1 Extend the assembly cable if necessary2 Open the front grille by pulling on the tabs on the lower right and left sides ofthe indoor unit3 Remove the screw securing the connector cover4 Pass the assembly cable through the rear of the indoor unit and connectthe assembly cable to terminals as seen in the picture Each wire is labeled with the corresponding terminal number5 Pass the other end of the cable through the 65mm hole in the wall6 Close the connector cover, tightening the screw carefully7 Close the front grille8 Remove the terminal board cover on the side of the outdoor unit9 Connect the cables to the terminals as seen in the picture Each wire is labeled with the corresponding terminal number Please make sure to use copper supply wires10 Connect the grounding conductor to the grounding terminals11 Close the terminal board cover, tightening the screw carefully12 Connect the power cable to the indoor unit In Russia and Europe, consult with the supply authority to determinethe supply system impedance before installation.Connecting the Assembly CablePower cable specificationUse AWG Cross sectional area (mm²)Main Power Supply 3-wirepower cable 3 or fewer 5 or moreIndoor Power Supply3-wire power cable 6 or fewer 5 or more-wire assembly cable 6 or fewer 5 or more Connect the power cable to the auxiliary circuit breaker.If every pole fails to connect to the power supply, it must beincorporated in a wire with a contact opening of ≥0.118inch(3mm).NL1(L) 2(N) F1 F21(L) 2(N)F1 F2E1EL N E2(N)1(L) F1 F22(N)1(L) F1 F2Indoor unit Screws on terminal block must notbe unscrewed with the torque lessthan 0 87ft•lb ( kgf•cm)Outdoor unit The designs and shape are subject tochange according to the modelModel “A”AQV09NAQVN 49 ft(5m)AQV8NAQV4N 98 4ft(30m)Circuit Breaker(Main power)09//8/4