Contents - Table Of Contents
- Table Of Contents
- Safety Instructions
- Features and Specifications
- Specifications
- Comparing Specifications with Existing Models
- Options Specifications
- Disassembly and Reassembly
- Standard Disassembly Drawings
- Checkpoints after Finishing a Service
- Troubleshooting
- Service Inspection Mode
- Exploded Views and
- MAIN (DMR77, DMR78)
- ASSY-DOOR (DMR77, DMR78)
- ASSY-TUB (DMR77, DMR78)
- ASSY-BASE (DMR77, DMR78)
- ASSY-SUMP (DMR77, DMR78)
- ASSY-CASE (DMR77, DMR78)
- MAIN (DMR57)
- ASSY-DOOR (DMR57)
- ASSY-TUB (DMR57)
- ASSY-BASE (DMR57)
- ASSY-SUMP (DMR57)
- ASSY-CASE (DMR57)
- PCB Diagram
- New PBA- Main PCB
- Old PBA - Detailed Specifications and Descriptions for Connectors and Relay Terminals (MAIN PBA)
- New PBA- Detailed Specifications and Descriptions for Connectors and Relay Terminals (MAIN PBA)
- Detailed Specifications and Descriptions for Connectors (TOUCH 7KEY - DMR77, DMR78)
- Detailed Specifications and Descriptions for Connectors (TOUCH 7KEY - DMR57)
- Detailed Specifications and Descriptions for Connectors (TOUCH 3KEY - DMR77,DMR78)
- Detailed Specifications and Descriptions for Connectors (DISPLAY LED - TOP - DMR77, DMR78 (DD07-00008A 8B))
- Detailed Specifications and Descriptions for Connectors (DISPLAY LED - FRONT - DMR57)
- Wiring Diagram
- Old Wiring Diagram (DMR57)
- New PBA - Wiring Diagram (DMR78, DMR77 , DMR57)
- Schematic Diagram
- TOUCH KEY (7KEY - DMR77, DMR78)
- TOUCH KEY (3KEY - DMR77, DMR78)
- TOUCH KEY (7KEY - DMR57)
- Reference
- Terminology
|
4. Troubleshooting4-3Error type Error mode Checking Method Corrective actionsWater supply error 4E1. Check whether the faucet is open. - Open the faucet.2. Check whether the water supply has been cut off. - Close the faucet and turn off the power. Wait until the water supplyresumes.3. Check whether any foreign material is in the Water Supply Line andthe Inlet Valve filter. - Remove the foreign material. Clean the filter with a brush.4. Check the connection for the Inlet Valve connector. - Reconnect the Inlet Valve connector.5. Check whether the coil in Inlet Valve is conductive (Remove theconnector before measuring.)Normal: Approx. 1.2 kΩ➢- Faulty: Replace the Inlet Valve.6. Check whether the Inlet Valve is operating normally.- Check the operation of the Inlet ValveNormal: 120V➢- Check the Inlet Valve Relay.: Check the voltage between the white wire of the Main PBACN1 connector and the brown wire of the CN14Normal: 120V (while operating)➢NEW PBA6-1.Check whether the Inlet Valve is operating normally.- Check the operation of the Inlet ValveNormal: 120V➢- Check the Inlet Valve Relay.: Check the voltage between the white wire of the Main PBACN101 connector and the brown wire of the CN201Normal: 120V (while operating)➢- Faulty: Replace the Main PBA assy.- Normal: Replace the Inlet ValveNEW PBA7. Check the Power Relay. - See the “Power Relay error”.8. Check whether the water supply stops after water is supplied for 5seconds. - Replace the Flow Meter.9. Check whether the water supply stops after water is supplied for 1or 5 minutes. - Check the water supply valve and increase the water pressure. PreviousNext |