Contents - Table Of Contents
- Table Of Contents
- Safety Instructions
- Features and Specifications
- Specifications
- Comparing Specifications with Existing Models
- Options Specifications
- Disassembly and Reassembly
- Standard Disassembly Drawings
- Checkpoints after Finishing a Service
- Troubleshooting
- Service Inspection Mode
- Exploded Views and
- MAIN (DMR77, DMR78)
- ASSY-DOOR (DMR77, DMR78)
- ASSY-TUB (DMR77, DMR78)
- ASSY-BASE (DMR77, DMR78)
- ASSY-SUMP (DMR77, DMR78)
- ASSY-CASE (DMR77, DMR78)
- MAIN (DMR57)
- ASSY-DOOR (DMR57)
- ASSY-TUB (DMR57)
- ASSY-BASE (DMR57)
- ASSY-SUMP (DMR57)
- ASSY-CASE (DMR57)
- PCB Diagram
- New PBA- Main PCB
- Old PBA - Detailed Specifications and Descriptions for Connectors and Relay Terminals (MAIN PBA)
- New PBA- Detailed Specifications and Descriptions for Connectors and Relay Terminals (MAIN PBA)
- Detailed Specifications and Descriptions for Connectors (TOUCH 7KEY - DMR77, DMR78)
- Detailed Specifications and Descriptions for Connectors (TOUCH 7KEY - DMR57)
- Detailed Specifications and Descriptions for Connectors (TOUCH 3KEY - DMR77,DMR78)
- Detailed Specifications and Descriptions for Connectors (DISPLAY LED - TOP - DMR77, DMR78 (DD07-00008A 8B))
- Detailed Specifications and Descriptions for Connectors (DISPLAY LED - FRONT - DMR57)
- Wiring Diagram
- Old Wiring Diagram (DMR57)
- New PBA - Wiring Diagram (DMR78, DMR77 , DMR57)
- Schematic Diagram
- TOUCH KEY (7KEY - DMR77, DMR78)
- TOUCH KEY (3KEY - DMR77, DMR78)
- TOUCH KEY (7KEY - DMR57)
- Reference
- Terminology
|
4. Troubleshooting4-7Error type Error mode Checking Method Corrective actionsHeater error HE1 1. Check the operation of the Thermistor. - See the “tE1 Error”.2. Check the Heater Relay. - See the “HE Error”.Water leakageerror LE Check whether there is any trace of water leakage in the shutter.Normal: No water leakage trace➢- Faulty: Check the leakage location. Replace the faulty part.- Nomral: Replace the Main PBA assy.Half load error PE1. Check the connections for the Distributor Motor connectors. - Reconnect the Distributor Motor connectors.2. Check whether the coil in Distributor Motor is conductive.: Remove the connectors before measuring.Normal: Approx. 2.6 kΩ➢- Faulty: Replace the Distributor Motor.3. Check whether half load is operating normally.- Check the half load operationNormal: 120V➢- Check the the operation of Distributor Motor Relay.: Check the operating voltage between the white wire of theMain PBA CN1 connector and the violet wire of the CN14connector.Normal: 120V (while operating)➢New PBA3-1.Check whether half load is operating normally.- Check the half load operationNormal: 120V➢- Check the the operation of Distributor Motor Relay.: Check the operating voltage between the white wire of theMain PBA CN101 connector and the violet wire of the CN201connector.Normal: 120V (while operating)➢- Faulty: Replace the Main PBA assy.4. Check the Power Relay. - See the “Power Relay error”.New PBA PreviousNext |