SAMSUNG IPX-G5X0 Installation Manual v1.0 Mar 201619IPX-G520S/G540S (ECU) Basic ConfigurationUse the following steps to connect to the serial console: Connect a serial cable to the console port of the system. Run a serial terminal program (I.E., PuTTY, etc.) on your PC and set the baud rate to 38,400. The default login ID is: admin / The default Password is: samsung*# Enter ‘cli’ to set up the basic gateway configuration. Select ‘1. Setup basic configuration’. Following the prompts enter the IP Address of the ECU, Gateway IP Address, and Subnet Mask. Enter the LAN IP Address of the main IPX-G500B, which this expansion cabinet will be connected to.Note: The IPX-G520S/G540S LAN port should be connected to the same LAN network as the IPX0-G500. Assign the sequence number from 1 to 6 for this expansion cabinet. It should be unique for eachgateway. After all information is entered it will ask if you want to reset the system to apply the changes. To reboot the system enter ‘yes’, otherwise enter ‘no’###### Please enter [IP/Gateway/Subnet Mask] of this ECU ######1. Enter ECU IP Address (Enter Key : 10.251.0.11 ) :2. Enter Gateway Address (Enter Key : 10.251.0.1 ) :3. Enter Subnet Mask (Enter Key : 255.255.255.0 ) :###### Please enter the IP Address of CMU ######1. Enter CMU IP Address (Enter Key : 10.251.0.10 ) :1. Enter this ECU number (Enter Key : 1) :End of Configuration. To apply it, please restart the system.Do you want to restart? (yes/no) :