E-28TroubleshootingDetection of errors If an error occurs during the operation, an LED flickers and the operation is stopped except the LED. If you re-operate the air conditioner, it operates normally at first, then detect an error again.LED Display on the receiver & display unitC OMPLETING THE INSTALLATIONDisplayed on appropriate indoorunit which is operatingDisplayed on appropriate indoorunit which is operatingDisplayed on appropriate indoorunit which is operatingDisplayed on outdoor unit1. Error of indoor unit: Displayedon the indoor unit regardlessof operation2. Error of outdoor unit:Displayed on the indoor unitwhich is operatingPower resetError of temperature sensor in indoor unit(OPEN/SHORT)Error of heat exchanger sensor in indoor unitError of heat exchanger OUT sensor in indoor unitError of outlet temperature sensor in indoor unit(OPEN/SHORT): For heat pump models onlyError of mixed operationError of outdoor temperature sensorError of COND sensorError of DISCHARGE sensor1. No communication for 2 minutes betweenindoor unit and outdoor unit(communication error for more than 2 minutes)2. Indoor unit receiving the communicationerror from outdoor unit3. Outdoor unit tracking 3 minute error4. When sending the communication errorfrom outdoor unit the mismatching of thecommunication numbers and installednumbers after completion of tracking.(communication error for more than2 minutes)X X XXX XXXXXXXXX XXXXXX On Flickering X Off If you turn off the air conditioner when the LED is flickering, the LED is also turned off. If you re-operate the air conditioner, it operates normally at first, then detect an error again.OperatingIndicatorsAbnormal conditions Green RedConcealed TypeStandard TypeLED Display