In the area emitting the highest reading, switch the meterto SLOW RESPONSE, and take a reading for minimum ofthree (3) seconds. We recommended the pattern outlineshown below when the door surface is surveyed.NOTE : Periodically check to be sure that the probe tip isnot worn or dirty.The following U.S. standard applies to microwave ovens :21 CFR 1030.10, Performance Standard for MicrowaveOvens.It requires that the power density of the microwaveradiation emitted by a microwave oven shall not exceedfive (5) milliwatts per square centimeter at any point 5centimeter (about 2 inches) or more from the externalsurface of the oven.All microwave ovens exceeding the emission level of4mW/cm 2 must be reported to Dept. of Service formicrowave ovens and the manufacturer immediately andthe owner should be told not to use the microwave ovenuntil it has been repaired completely.If a microwave oven is found to operate with the door open,report to Dept. of Service, the manufacturer and CDRH*immediately. Also tell the owner not to use the oven.*CDRH : Center for Device and Radiological Health.The interlock monitor switch acts as the final safety switchprotecting the customer from microwave radiation. If theinterlock monitor switch operates to blow the fuse withinterlocks failed, you must replace all interlock switchesprimary and secondary interlock switches and the monitorswitch with new ones because the contacts of thoseinterlock switches may be melted and welded together.CAUTIONCAUTIONCAUTIONCAUTIONCAUTIONFor micrFor micrFor micrFor micrFor microwave enerowave enerowave enerowave enerowave energy emissiongy emissiongy emissiongy emissiongy emissionOn every service calls, check for microwave energyemission, must be made according to the following manner.MeasurMeasurMeasurMeasurMeasurement of enerement of enerement of enerement of enerement of energy emissiongy emissiongy emissiongy emissiongy emissionMeasurement must be made with the microwave ovenoperating at its maximum output and containing a load of275±15 milliliters of tap water initially at 20o±5o celsius (68±9o F) placed within the cavity at the center.NOTE : The water container must be a 600 milliliter beakerand made of an electrically none conductivematerial such as glass or plastic.The cook tray must be in place when measuringemission.A properly operating door and seal assembly will normallyregister emission on greater than 4mW/cm 2 to allow formeasurement uncertainty with the cooking shelf or tray inplace.All repairs must be performed in such a mannerAll repairs must be performed in such a mannerAll repairs must be performed in such a mannerAll repairs must be performed in such a mannerAll repairs must be performed in such a manner thatthatthatthatthatmicrmicrmicrmicrmicrowave enerowave enerowave enerowave enerowave energy emission argy emission argy emission argy emission argy emission are minimal.e minimal.e minimal.e minimal.e minimal.Follow the instructions supplied with a detector being usedand performed an R.F. emission test around the door frontand edges and all edges and vent of the outer case. Thecabinet (wrapper) must be in place and the oven fullyassembled.When performing emission survey, with the meter on FASTRESPONSE the movement of a detector probe shall notexceed one (1) inch per second.- i -