99AppendixStatus Read CommandsThe command is sent from PC to the projector withthe format below;“CR” [Command] [CR]Command: one character (refer to the commandtable below.)The projector decodes the command and returns the'Character string' with the format below;FormatCommand Function Returnvalue Projector statusCR0 Status Read00 Power On80 Stand-by mode40 Countdown20 Cooling down10 Power Malfunction28 Cooling down at the temperature anomaly24 Cooling down at Power Management mode04 Power Management mode after Cooling down21 Cooling down after the projector is turned off when the lampsare out.81 Stand-by mode after Cooling down when the lamps are out.88 Stand-by mode after Cooling down at the temperatureanomaly.2C Cooling down when the projector is turned off by the shuttermanagement function.8C Stand-by mode after Cooling down by the shuttermanagement function.CR6 Temperature Read %1 %2%1 = Temperature at Sensor 1 (˚C)%2 = Temperature at Sensor 2 (˚C)(ex.) %1 = 12.3 (˚C), %2 = 23.4 (˚C)--> The projector returns “ 12.3 23.4”.(For each sensor, two digit and the tenth place numbers aredisplayed with a space between each temperature.)? Communication failureThe tables on page 98 show the typical command lists for controlling the projector. Please consult your localdealer for further information of other commands.