PLC-WL2500/WL2501 Basic Serial Command Specifications16/256.34. IMAGE (Toggle) CommandCommand “C27”[CR]Detail Switch Image Setting status.This command works the same as “IMAGE” button of the remote control.Response Acceptable [ACK] [CR]Unacceptable “ ”[CR]6.35. Direct on Setting CommandCommand “C28” [CR]Detail Enable Direct on.This status is stored in EEPROM and retained regardless of Power OFF/ON.Response Acceptable [ACK] [CR]Unacceptable “ ”[CR]6.36. Direct on Cancel CommandCommand “C29” [CR]Detail Disable Direct on.This status is stored in EEPROM and retained regardless of Power OFF/ON.Response Acceptable [ACK] [CR]Unacceptable “ ”[CR]6.37. Power Management Ready CommandCommand “C2A” [CR]Detail Set Power Management to Ready mode.This status is stored in EEPROM and retained regardless of Power ON/OFF.ResponseAcceptable [ACK] [CR]Unacceptable “ ”[CR]6.38. Power Management OFF CommandCommand “C2B” [CR]Detail Set Power Management to OFF mode.This status is stored in EEPROM and retained regardless of Power ON/OFF.Response Acceptable [ACK] [CR]Unacceptable “ ”[CR]6.39. Power Management Shut down CommandCommand “C2E” [CR]Detail Set Power Management to Shut down mode.This status is stored in EEPROM and retained regardless of Power OFF/ON.Response Acceptable [ACK] [CR]Unacceptable “ ”[CR]