PLC-WXU300 Basic Serial Command Specifications22/23information of temperature anomaly is canceled and normal operation is executed.“24” [CR]Status: Processing Power Save / Cooling DownPower management function in Setting menu works and the status goes to Power Save/ Cooling Down.During this time, Functional Execution Commands are invalid (not executed).This status moves to Power Save at set hours after the operation of Cooling Down.Status No signal Power Save / Cooling Down Power SaveResponse “00” “24” “04”5 minutes with no signal After about 90 sec.“04” [CR]Status: Power SaveThis shows that it moves to Power Save status by Power management function inSetting menu.“21” [CR]Status: Cooling Down in process after turned off due to lamp failureWhen a projector is turned off because of lamp failure, it automatically starts CoolingDown operation, in which the projector returns “21” [CR].“81” [CR]Status: Standby after Cooling Down due to lamp failureThis value is returned when Cooling Down operation due to lamp failure has beencompleted and the status has been moved to Standby. The status is kept until the nextoperation starts.7.5. Input Mode Read CommandCommand “CR1” [CR]Detail Get the selected Input No.ResponseAcceptable “%1” [CR]%1”1” = Computer 1 is selected”2” = Computer 2 is selected“3” = HDMI is selected“4” = Video is selected“5” = S-video is selectedUnacceptable “?” [CR]