PLC-XF1000 Basic Serial Command Functional Specifications17/24・ “10” [CR]Status: Power FailureWhen the power supply voltage inside the projector reaches abnormal level, the statusautomatically moves to Power OFF.※ Abnormal power supply voltage includes;- Filter abnormal status- Shutter abnormal statusThe projector returns “10” [CR], which indicates the status moves to Power OFF due topower failure. Fan also stops.・ “28” [CR]Status: Cooling Down due to Abnormal Temperature in process.When the internal temperature rises abnormally, it automatically starts Cooling Downprocess. Response value for this status is “28” [CR].Even if the temperature comes down during this process, the given Cooling Down processis executed and it moves to Standby mode.・ “02” [CR]Status: RS-232C Commands cannot be acceptedWhen receiving this response, re-send Status Read Command.・ “24” [CR]Status: Power Management Cooling Down in process.When Power Management function in setting menu is set to ON, continuous 5 minutes ofno signal status leads to turning off lamps and starting Cooling Down operation (GreenLED on the projector body is turned off).During this period, any Functional Execution Command cannot be accepted.The Power Management Cooling Down operation continues about 90 seconds, then thestatus moves to Power Management.Status: No signal Power Management Cooling down Power ManagementResponse: “00” “24” “04”5 minutes of no signal status After about 90 sec.・ “04” [CR]Status: Power ManagementThis indicates it has moved to Power Management status according to the setting of PowerManagement function in Setting menu.