PLC-XF1000 Basic Serial Command Functional Specifications20/247.7 Temp Read CommandCOMMAND “CR6” [CR]DetailGet the temperature information inside projectorWith more than one temperature sensors installed in the projector, it is possibleto get all temperatures at once.Acceptable “%1_%2_%3” [CR]%1%2%1 = temperature at Sensor 1%2 = temperature at Sensor 2%3 = temperature at Sensor 3Temperature data is expressed as “00.0”.When the temperature goes under 0, the first character is “-” like“-05.5” [CR].When no temperature data returns due to hardware problemsthe first character is “E” like” E00.0” [CR].With more than one temperature sensors installed, the projectorreturns the values in series.Ex) “_31.5_ _35.2_ _33.4” [CR]Each sensor data follows in sequence with one space betweeneach of them.ResponseUnacceptable “?” [CR]7.8 Lamp Mode Read CommandCOMMAND “CR7” [CR]Detail Get current Lamp Mode in the multiple-lamp projector.When there is any fail lamp, also can get the information about.Acceptable “%1” [CR]%1ex: ”0F”[CR]The first digit indicates Lamp Mode.0 = 2lamp Mode1 = 1lamp Mode (Lamp No.1 used)2 = 1lamp Mode (Lamp No.2 used)The second digit indicates if the lamp is ON or OFF.Data is shown as “0-9” and “A-F”, which is described in 4-bitdata. Assign each bit for each lamp data.ex: 0 = ALL is OFF1 = No.1 is ON, the other is OFF2 = No.2 is ON, the other is OFF3 = ALL is ONResponseUnacceptable “?” [CR]7.9 PC Type Read CommandCOMMAND “CR9” [CR]Detail Get the currently displayed PC TypeAcceptable “%1” [CR]%1“Stand_by” ------------------------------------- Standby“AV_Mode” ------------------------------------- AV ModeCurrent Table such as “UXGA1” ---------- PC Mode“Go_PC_adj.” --------------------------------- Auto“No_signal” ------------------------------------ No signalResponseUnacceptable “?” [CR]