83Status Read CommandAppendixThe command is sent from PC to the projector withthe format below;'CR' [Command] 'CR'Command: one character (refer to the commandtable below.The projector decodes the command and returns the'Character string' with the format below;FormatCommand Function ProjectorReturn Projector statusCR0 Status Read00 Power On80 Stand-by mode40 Countdown20 Cooling down10 Power Malfunction28 Cooling down at the temperature anomaly02 Unable to receive the RC232C command.24 Cooling down at Power Management mode04 Power Management mode after Cooling down21 Cooling down after the projector is turned off when the lampsare out.81 Stand-by mode after Cooling down when the lamps are out.88 Stand-by mode after Cooling down at the temperatureanomaly.2C Cooling down when the projector is turned off by the shuttermanagement function.8C Stand-by mode after Cooling down by the shuttermanagement function.CR6 Temperature Read S1 S2 S3S1 = Temperature at Sensor 1 (˚C)S2 = Temperature at Sensor 2 (˚C)S3 = Temperature at Sensor 3 (˚C)(ex.) S1 = 12.3˚C, S2 = 23.4˚C, S3 = 34.5˚C--> The projector displays “12.3 23.4 34.5”(For each sensor, two digit and the tenth place numbers aredisplayed with a space between each temperature.)? Communication failureThe tables on page 82 and 83 show the typical command lists for controlling the projector. Please consult yourlocal dealer for further information of other commands.