-47-Electrical AdjustmentsGroup/Item Item Name Function Initial Range Note10 Close Limit Dimmer 0 728 0-102311 Close Limit Dimmer 1 714 0-102312 Close Limit Dimmer 2 684 0-102313 Close Limit Dimmer 3 654 0-102314 Close Limit Dimmer 4 624 0-102315 Close Limit Dimmer 5 594 0-102316 Close Limit Dimmer 6 564 0-102317 Close Limit Dimmer 7 534 0-102318 Close Limit Dimmer 8 504 0-102319 Close Limit Dimmer 9 474 0-102320 Close Limit Dimmer 10 444 0-102321 Close Limit Dimmer 11 414 0-102322 Close Limit Dimmer 12 384 0-102323 Close Limit Dimmer 13 354 0-102324 Close Limit Dimmer 14 324 0-102325 Close Limit Dimmer 15 294 0-102330 Update Interval 18/18 0-1023 (AV/PC)Group230 VBI Slice Level0 Generic Initial Slicing Level PW190 register 0xE344 9 0-2551 Generic High Level Threshold PW190 register 0xE345 0 0-2552 Generic Low Level Threshold PW190 register 0xE346 0 0-2553 Generic Minimum Low Level PW190 register 0xE347 0 0-2554 Generic Maximum High Level PW190 register 0xE348 255 0-255Group250 FAN Control0 FAN1 MIN ADJUST (DAC) DAC Output for FanAdjust the tolerance of DAC and FanVolage.* Lamp mode is forced Eco38 0 - 2551 FAN1 MAX ADJUST (DAC) 233 0 - 2552 FAN2 MIN ADJUST (DAC) 38 0 - 2553 FAN2 MAX ADJUST (DAC) 230 0 - 2554 FAN3 MIN ADJUST (DAC) 31 0 - 2555 FAN3 MAX ADJUST (DAC) 214 0 - 2556 Not used7 Not usedGroup252 FAN Option0 HI-LAND SWITCH 0: Normal, 1: Hi-Land, 2-4: Hi-Land1-3 0 0 - 51 SAFETY SWITCH For test purpose 0 0 - 62 FAN MANUAL SWITCH 0: Auto, 1: Manual 0 0 - 33 FAN1 MANUAL VOLTAGE Fan Voltage (unit : 0.1V)Effective only when Fan Manualswitch is 1100 0 - 2554 FAN2 MANUAL VOLTAGE 100 0 - 2555 FAN3 MANUAL VOLTAGE 100 0 - 2556 Not used -PLC-XK2200Group253 Fan tem error Setting (Memorized) Normal Ceiling HiLand-NormalHiLand-Ceiling0 Temp A Warning (High) 45 51 48 50 -1 Temp B Warning (High) 58 63 58 63 -2 Temp C Warning (High) 63 68 63 68 -3 Temp B-A Warning(High) 100 100 100 100 -4 Temp C-A Warning(High) 100 100 100 100 -5 Temp A Warning (Normal) Temp. A to judge the Temp Error atNormal (Room) 45 50 46/47 48/49 30-100 On1/On26 Temp B Warning (Normal) Temp. B to judge the Temp Error atNormal (Panel) 58 63 58 63 30-1007 Temp C Warning (Normal) Temp. C to judge the Temp Error atNormal (Lamp) 63 68 63 68 30-1008 Temp B-A Warning (Normal) Temp. B-A to judge the Temp Error atNormal (Clogging Det.) 100 100 100 100 0-1009 Temp C-A Warning (Normal) Temp. C-A to judge the Temp Error atNormal (Clogging Det.) 100 100 100 100 0-10010 Temp A Warning (Eco) Temp. A to judge the Temp Error atEco (Room) 50 51 46 47/48 30-100 On1/On211 Temp B Warning (Eco) Temp. B to judge the Temp Error atEco(Panel) 63 63 58 58 30-10012 Temp C Warning (Eco) Temp. C to judge the Temp Error atEco(Panel) 67 67 62 62 30-10013 Temp B-A Warning (Eco) Temp. B-A to judge the Temp Error atNormal (Clogging Det.) 100 100 100 100 0-10014 Temp C-A Warning (Eco) Temp. C-A to judge the Temp Error atNormal (Clogging Det.) 100 100 100 100 0-100