PLC-XL50 Expand Serial Command Functional Specifications27/518.10 Setting Command8.10.1 CF_BBACK CommandCommand “CF_BBACK_%1”[CR]%1 “ON” ----------------------------- Select Blue Back“OFF” ---------------------------- Cancel Blue BackDetailsSet / Cancel Blue Back (Available only in the normal Power ON status)The value set by this command is stored in EEPROM and its setting is effectiveeven after ALL is OFF.Acceptable “000”[CR]ResponseUnacceptable “Error Code”[CR]8.10.2 CF_DISP CommandCommand “CF_DISP_%1”[CR]%1“ON” ----------------------------- Select Display“OFF” ---------------------------- Cancel Display“CNTDWNOFF” --------------- Count down OFFDetailsSet / Cancel Display (Available only in the normal Power ON status)The value set by this command is stored in EEPROM and its setting is effectiveeven after ALL is OFF.Acceptable “000”[CR]ResponseUnacceptable “Error Code”[CR]8.10.3 CF_LOGO CommandCommand “CF_LOGO_%1”[CR]%1“OFF” ----------------------------- Cancel Logo display“DEFAULT” ---------------------- Set Default Logo display“USER” --------------------------- Set Captured Logo displayDetailsSet / Cancel Logo (Available only in the normal Power ON status)The value set by this command is stored in EEPROM and its setting is effectiveeven after ALL is OFFIn case capture is not yet excuted, Projector returns error code “101” by receiving“User”Acceptable “000”[CR]ResponseUnacceptable “Error Code”[CR]”101” --------- When Logo is locked by Logo PIN code8.10.4 CF_CEIL CommandCommand “CF_CEIL_%1”[CR]%1 “ON” --------------------------- Select Ceiling“OFF” ------------------------- Cancel CeilingDetailsSet / Cancel Ceiling (Available only in the normal Power ON status)The value set by this command is stored in EEPROM and its setting is effectiveeven after ALL is OFFAcceptable “000”[CR]ResponseUnacceptable “Error Code”[CR]