PLC-XU305A/355A Expand Serial Command Functional Specifications54/689.8 Screen Status Read Command9.8.1 CR_SCREEN CommandCommand “CR_SCREEN”[CR]Details Get selected on-screen image sizeResponseAcceptable “000_%a”[CR]%aInputisPC“NORMAL” --------------- Normal mode is selected“TRUE” -------------------- True mode is selected“WIDE” --------------------- Wide mode is selected“FULL” --------------------- Full mode is selected“CUSTOM” ---------------- Custom mode is selectedWhen the screen is set to D.Zoom, projector returns the previousstatus (NORMAL )InputisVideo“NORMAL” --------------- Normal mode is selected“WIDE” -------------------- Wide is selected“CUSTOM” --------------- Custom size is selectedUnacceptable“Error Code”[CR] ------ When the command is invalid due tocondition such as Input source“?”[CR] ----------------------- When unclear command is received9.8.2 CR_ KYSTNMODE CommandCommand “CR_KYSTNMODE”[CR]Details Get setting status of Keystone Store ModeResponseAcceptable “000_%a”[CR]%a “STR” ---------------------- Store mode is “Store”“RST” ---------------------- Store mode is “Reset”Unacceptable “Error Code”[CR]9.8.3 CR_VSCALE CommandCommand “CR_VSCALE”[CR]Details Get setting status of Vertical Scale Store ModeResponseAcceptable “000_%1[CR]%1 “-32” ~ “032”Unacceptable “Error Code”[CR]9.8.4 CR_VPOS CommandCommand “CR_VPOS”[CR]Details Get setting status of Vertical Position Store ModeResponseAcceptable “000_%1”[CR]%1 “-15” ~ “015”Unacceptable “Error Code”[CR]9.8.5 CR_HSCALE CommandCommand “CR_HSCALE”[CR]Details Get setting status of Horizontal Scale Store ModeResponseAcceptable “000_%1”[CR]%1 “-32” ~ “032”Unacceptable “Error Code”[CR]