– 17 –Adjustment value determination is effectuated using the "STDAFPOS" and "FOCUS" values.If FOCUS=focus1, focus2, focus3, focus4 and the adjustmentvalues fulfill the conditions below, they are determined as withinspecifications.Adjustment value determination997<=STD_AFPOS<=1097focus1 = 0, -20<=focus2<=+25-40<=focus3<=+45, -30<=focus4<=+353. AWB AdjustmentPreparation:POWER switch: ONAdjusting method:1. When setting the camera in place, set it to an angle so thatnothing appears in any part of the color viewer except thewhite section. (Do not enter any light.)2. Double-click on the DscCalDi.exe.3. Click the AWB, and click the Yes.4. AWB adjustment value will appear on the screen.5. Click the OK.Adjustment value determination is effectuated using the "AGC",“CHECK" and "MS" values.If AGC=a1, a2, a3, a4, a5, CHECK=wc0, wc1, wc2 andMS=MS1, MS2, the adjustment values fulfill the conditions be-low, they are determined as within specifications.Adjustment value determination50300wc0=128 ± 2, wc1=128 ± 2, wc2=130 ± 401550450Adjustment values other than the above are irrelevant.4. CCD White Point Defect Detect AdjustmentPreparation:POWER switch: ONAdjustment method:1. Double-click on the DscCalDi.exe.2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.3. After the adjustment is completed, OK will display.4. Click the OK.5. CCD Black Point And White Point Defect DetectAdjustment In LightedCameraPattern box(color viewer)CameraPattern box(color viewer)DscCalDi xOKFocus ResultSTD_AFPOS=1038FOCUS=0,-11,9,14!Dsc Calibration xOKAWB Result:1:AGC=176,345,513,682,8524F_AGC=0,0,0WB=278,512,648CHECK=127,128,142MS=1728,2102Copy PreviousNext |