InstallationDIGIgarde PLUS User GuideLast Change Copyright © 2012 TDSi13 May, 2016 Page 152.3.32.3.32.3.32.3.3 Power connectionPower connectionPower connectionPower connectionYou can power the unit directly using a DC supply or by using PoE (Power overEthernet).CAUTION! Allow a period of 10 minutes before reapplying power if suppliesare switched between PoE and a DC supply of vice versa.It is strongly recommended that if the reader is connected to an accesscontrol unit it is also powered from this to prevent damage resulting fromany difference in earth potentials.Using a DC power supplyUsing a DC power supplyUsing a DC power supplyUsing a DC power supplyTo power the unit, connect red and black wires labelled Power to a power supplyrated at 10 to 14 VDC and capable of supplying a current of 500mA.Label Wire Colour Signal DescriptionPower Black 0V Power GNDRed +12V Power InputUsing PoEUsing PoEUsing PoEUsing PoEConnect the DIGIgarde PLUS to a PoE-enabled network device such as anEthernet switch using the RJ45 connector and an appropriate CAT5 (or higher)cable. You can also ‘inject’ power into the network cable using a midspan powersupply or PoE injector.2.3.42.3.42.3.42.3.4 WiegandWiegandWiegandWiegand/Magnetic Clock Data to a compatible ACU/Magnetic Clock Data to a compatible ACU/Magnetic Clock Data to a compatible ACU/Magnetic Clock Data to a compatible ACUConnect the wire WD0-OUT on the reader to Data 0 on the access control unit andthe wire WD1-OUT on the reader to Data 1 on the access control unit.Label Wire Colour Signal DescriptionWG OUTYellow WD0-OUT Wiegand Output, Data 0White WD1-OUT Wiegand Output, Data 1Black GND Wiegand GNDBlue LED LED