Operator's ManualFourth Edition · First PrintingPart No. 114340 Z-45/25 • Z-45/25J • Z-51/30J 9Work Area SafetyElectrocution HazardsThis machine is not electrically insulated and willnot provide protection from contact with orproximity to electrical current.Maintain safe distances from electrical power linesand apparatus in accordance with applicablegovernmental regulations and the following chart.Line Voltage Required Clearance0 to 50KV 3.0 m50 to 200KV 4.6 m200 to 350KV 6.1 m350 to 500KV 7.6 m500 to 750KV 10.6 m750 to 1000KV 13.7 mAllow for platform movement, electrical line sway orsag and beware of strong or gusty winds.Keep away from the machine if it contactsenergized power lines. Personnel on the ground orin the platform must not touch or operate themachine until energized power lines are shut off.Do not use the machine as a ground for welding.Do not operate the machine during lightning orstorms.Tip-over HazardsOccupants, equipment and materials shall notexceed the maximum platform capacity.Maximum platform capacity 227 kgMaximum capacityMachine equipped withAircraft Protection Package 200 kgMaximum occupants 2The weight of options and accessories, such aspipe cradles, panel cradles and welders, will reducethe rated platform capacity and must be factoredinto the total platform load. See the decals with theoptions.If using accessories, read, understand and obeythe decals and instructions with the accessory.