- 78 -4.7 Laser on timeThis parameter sets the maximum time decode processing continues during ascan attempt. It is programmable in 0.1 second increments from 0.50 to 3.0seconds.To set a Laser On Time, scan the bar code below. Next scan two numeric barcodes beginning on Appendix B that correspond to the desired on time. Singledigit numbers must have a leading zero. For example, to set an on time of 0.5seconds, scan the bar code below, then scan the "0", "0" and "5" bar codes; toset an on time of 10.5 seconds, scan the bar code below, then scan the "1", "0"and "5" bar codes. To change the selection or cancel an incorrect entry, scanCancel on Appendix B.4.8 Aim durationIt is programmable in 0.1 second increments from 0.0 to 2.0 seconds. No aimpattern is visible when the value is 0.0.To set an aim duration, scan the bar code below. Next scan two numeric barcodes beginning on Appendix B that correspond to the desired aim duration.Single digit numbers must have a leading zero. For example, to set an aimduration of 0.5 seconds, scan the bar code below, then scan the “0” and “5” barcodes. To change the selection or cancel an incorrect entry, scan Cancel onAppendix B.