0020166663_03 VWZ MEH 61 Installation instructions and instructions for use 15EN6.3 Resetting the Electrical back-up heaterb Caution!Risk of material damage► For this measure, an advancecheck is required and this mustonly be carried out by acompetent person.In case of an abnormal increase in water temperature, theheating element's safety thermostat may be triggered (Referto the installation manual control box+).It has to be reset manually.i NotesLet the heating element cool before resetting.11 Reset button► Press the reset button (1).6.4 Checking tightness► Check the water-tightness of the system.6.5 Checking the electrical installation► Check the electrical installation observing all relevantregulations.6.5.4.1 Vérifi cation des câbles► If the power cable of this product is damaged, then toprevent danger, only the manufacturer, the after-salesservice or similarly qualified persons shall replace thepower cable.7 Decommissioning► Isolate the product from the power mains.► Drain the appliance (see chapter 6.2).► De-install the product.► Recycle or dispose the product and its components (seechapter 8).8 Recycling and disposal► The competent person who installed your product isresponsible for the disposal of the packaging.If the product is identified with this symbol:► In this case, do not dispose of the product with householdwaste.► Instead, hand in the product to a collection centre for oldelectrical or electronic appliances.If the product contains batteries that are markedwith this symbol, these batteries may contain substancesthat are hazardous to human health and the environment.► In this case, dispose of the batteries at a collection pointfor batteries.9 Technical dataDescription UnitNet Weight kg 10Max. water pressure bar 3.0Mpa 0.3Min. water pressure bar 0.5Mpa 0.05ElectricalVoltage / frequency V~/Hz 230/50 230/50 400/50Maximum electricalconsumption kW 6 4 6Electrical protection A 30 20 10Index of electricalprotection IP X1DECOMMISSIONING