Instructions for Use, Installation and Servicing ecoMAX pro2412 CommissioningDANGER!Note that if the boiler is run with an emptycondensate trap there is a danger that fumesmight escape into the room and causepoisoning. For this reason, it is important toensure that the trap is topped up each time theunit is cleaned.12.7 User Controls and OptionsThe mains/reset switch is used to restart the boiler aftera fault condition has occurred, i.e. ignition failure.The user display (see section 3.3) allows the user to setthe desired central heating temperature.12.8 Temperature DisplayThe boiler shows the operating temperature of the unit.12.9 Pump Exercise ProgrammeAfter a power cut or every 24 hour in frost setting/summer mode the pump will run for one minute toprevent it from sticking. This will also occur duringnormal operating if there is no demand for more than 24hours.12.10 Hand over to userInstruct and demonstrate the lighting procedure andadvise the user on the safe and efficient operation of theboiler. Instruct on and demonstrate the operation of anyheating system controls.Advise that to ensure the continued efficient and safeoperation of the boiler it is recommended that it ischecked and serviced at regular intervals. The frequencyof servicing will depend upon the installation conditionsand usage, but in general, once a year should beadequate.Draw attention, if applicable, to the current issue of theGas Safety (Installation and Use) Regulations, Section35, which imposes a duty of care on all persons who letout any property containing a gas appliance.It is the Law that any servicing is carried out by acompetent person.Advise the user that, like all condensing boilers thisappliance will produce a plume of condensation from theflue terminal in cool weather. This is due to the highefficiency and hence low flue gas temperature of theboiler.Advise the user of the precautions necessary to preventdamage to the system, boiler and the building, in theevent of the heating system being out of use during frostor freezing conditions.Advise the user that the permanent mains electricalsupply SHOULD NOT be switched off, as the built infrost protection and pump saver program would not beoperable.Reminder, leave these instructions including the‘Benchmark’ logbook with the user.